Skip to main navigation Skip to search Skip to main content

10.5 T In Vivo Head Imaging With Universal RF Shimming

  • Young Woo Park
  • , Simon Schmidt
  • , Wolfgang Bogner
  • , Gregory J Metzger
  • , Małgorzata Marjańska

Research output: Contribution to journal › Article › peer-review

Abstract

PURPOSE: Brain MR imaging at 10.5 T ultra-high field offers significant improvements in signal-to-noise ratio (SNR), but faces challenges with B1 + inhomogeneity. Parallel-transmission (pTx) can be used to achieve a more uniform RF field distribution, but necessitates the use of B1 + calibration in the region of interest. This study explores a universal B1 + shim solution on 10.5 T that could eliminate the need for time-consuming subject-specific B1 + calibration.

METHODS: B1 + data from 7 participants (19 sessions) were used to develop the universal B1 + shim, which was then validated against traditional subject-specific approaches using T1-weighted MP2RAGE structural images in 5 participants (6 sessions). Statistical comparisons of tissue and subcortical segmentations were conducted using popular neuroimaging tools SPM and FreeSurfer, respectively.

RESULTS: The universal shim rapidly converged with a small training dataset, likely due to consistent positioning and the simplicity of B1 + shimming used for head imaging. Whole-brain tissue segmentation showed no statistically significant differences between universal and subject-specific solutions, with only minor variations near the ventricles and inferior brain regions in the detailed subcortical segmentation. The proposed universal B1 + shim reduces examination time by removing the need for separate data acquisition and optimization.

CONCLUSION: These findings suggest that the universal B1 + shim is a viable substitute for subject-specific approaches, offering a more efficient solution for neuroimaging applications. Additionally, it confirms that 10.5 T MRI can produce reliable structural brain imaging data, paving the way for broader adoption of ultra-high field MRI in neuroimaging research.

Original languageEnglish
Pages (from-to)2776-2785
Number of pages10
JournalMagnetic Resonance in Medicine
Volume95
Issue number5
DOIs
StatePublished - May 2026
Externally publishedYes

Keywords

  • Humans
  • Magnetic Resonance Imaging/methods
  • Brain/diagnostic imaging
  • Image Processing, Computer-Assisted/methods
  • Signal-To-Noise Ratio
  • Head/diagnostic imaging
  • Algorithms
  • Female
  • Male
  • Reproducibility of Results
  • Adult
  • Radio Waves
  • Image Enhancement/methods
  • Calibration

Fingerprint

Dive into the research topics of '10.5 T In Vivo Head Imaging With Universal RF Shimming'. Together they form a unique fingerprint.

Cite this