TY - JOUR
T1 - Advanced partial occlusion controller allows for increased precision during targeted regional optimization in a porcine model of hemorrhagic shock
AU - Lauria, Alexis L.
AU - Kersey, Alexander J.
AU - Mares, John A.
AU - Taheri, Branson D.
AU - Bedocs, Peter
AU - White, Paul W.
AU - Burmeister, David M.
AU - White, Joseph M.
N1 - Publisher Copyright:
© Wolters Kluwer Health, Inc. All rights reserved.
PY - 2022/4/1
Y1 - 2022/4/1
N2 - BACKGROUND Targeted regional optimization (TRO), a partial resuscitative endovascular balloon occlusion of the aorta strategy, may mitigate distal ischemia and extend the window of effectiveness for this adjunct. An automated device may allow greater control and precise regulation of flow past the balloon, while being less resource-intensive. The objective of this study was to assess the technical feasibility of the novel advanced partial occlusion controller (APOC) in achieving TRO at multiple distal pressures. METHODS Female swine (n = 48, 68.1 ± 0.7 kg) were randomized to a target distal mean arterial pressure (MAP) of 25 mm Hg, 35 mm Hg, or 45 mm Hg by either manual (MAN) or APOC regulation (n = 8 per group). Uncontrolled hemorrhage was generated by liver laceration. Targeted regional optimization was performed for 85 minutes, followed by surgical control and a 6-hour critical care phase. Proximal and distal MAP and flow rates were measured continuously. RESULTS At a target distal MAP of 25 mm Hg, there was no difference in the MAP attained (APOC: 26.2 ± 1.05 vs. MAN: 26.1 ± 1.78 mm Hg) but the APOC had significantly less deviance (10.9%) than manual titration (14.9%, p < 0.0001). Similarly, at a target distal MAP of 45 mm Hg, there was no difference in mean pressure (44.0 ± 0.900 mm Hg vs. 45.2 ± 1.31 mm Hg) but APOC had less deviance (9.34% vs. 11.9%, p < 0.0001). There was no difference between APOC and MAN in mean (34.6 mm Hg vs. 33.7 mm Hg) or deviance (9.95% vs. 10.4%) at a target distal MAP of 35 mm Hg, respectively. The APOC made on average 77 balloon volume adjustments per experiment compared with 29 by manual titrations. CONCLUSION The novel APOC consistently achieved and sustained precisely regulated TRO across all groups and demonstrated reduced deviance at the 25 mm Hg and 45 mm Hg groups compared with manual titration.
AB - BACKGROUND Targeted regional optimization (TRO), a partial resuscitative endovascular balloon occlusion of the aorta strategy, may mitigate distal ischemia and extend the window of effectiveness for this adjunct. An automated device may allow greater control and precise regulation of flow past the balloon, while being less resource-intensive. The objective of this study was to assess the technical feasibility of the novel advanced partial occlusion controller (APOC) in achieving TRO at multiple distal pressures. METHODS Female swine (n = 48, 68.1 ± 0.7 kg) were randomized to a target distal mean arterial pressure (MAP) of 25 mm Hg, 35 mm Hg, or 45 mm Hg by either manual (MAN) or APOC regulation (n = 8 per group). Uncontrolled hemorrhage was generated by liver laceration. Targeted regional optimization was performed for 85 minutes, followed by surgical control and a 6-hour critical care phase. Proximal and distal MAP and flow rates were measured continuously. RESULTS At a target distal MAP of 25 mm Hg, there was no difference in the MAP attained (APOC: 26.2 ± 1.05 vs. MAN: 26.1 ± 1.78 mm Hg) but the APOC had significantly less deviance (10.9%) than manual titration (14.9%, p < 0.0001). Similarly, at a target distal MAP of 45 mm Hg, there was no difference in mean pressure (44.0 ± 0.900 mm Hg vs. 45.2 ± 1.31 mm Hg) but APOC had less deviance (9.34% vs. 11.9%, p < 0.0001). There was no difference between APOC and MAN in mean (34.6 mm Hg vs. 33.7 mm Hg) or deviance (9.95% vs. 10.4%) at a target distal MAP of 35 mm Hg, respectively. The APOC made on average 77 balloon volume adjustments per experiment compared with 29 by manual titrations. CONCLUSION The novel APOC consistently achieved and sustained precisely regulated TRO across all groups and demonstrated reduced deviance at the 25 mm Hg and 45 mm Hg groups compared with manual titration.
KW - Noncompressible torso hemorrhage
KW - REBOA
KW - automated partial REBOA
KW - hemorrhagic shock
KW - partial REBOA
UR - http://www.scopus.com/inward/record.url?scp=85126841108&partnerID=8YFLogxK
U2 - 10.1097/TA.0000000000003493
DO - 10.1097/TA.0000000000003493
M3 - Article
C2 - 35320156
AN - SCOPUS:85126841108
SN - 2163-0755
VL - 92
SP - 735
EP - 742
JO - Journal of Trauma and Acute Care Surgery
JF - Journal of Trauma and Acute Care Surgery
IS - 4
ER -