TY - JOUR
T1 - Comparison of operation time, efficacy and safety between through-the-scope stent and over-the-while stent in malignant central airway obstruction
T2 - a multi-center randomized control trial
AU - Zeng, Da Xiong
AU - Cheng, Zhao Zhong
AU - Lv, Xue Dong
AU - Chen, Cheng Shui
AU - Wang, Ji Wang
AU - Browning, Robert
AU - Wang, Ko Pen
AU - Huang, Jian An
AU - Dutau, Hervé
AU - Kheir, Fayez
AU - Ke, Ming Yao
AU - Jiang, Jun Hong
N1 - Publisher Copyright:
© 2022 AME Publishing Company. All rights reserved.
PY - 2022/8
Y1 - 2022/8
N2 - Background: Self-expandable metallic (SEM) airway stents are an important approach to treating malignant central airway obstruction (CAO). Standard over-the-while (OTW) stent needs the guidance of a guide-wire. It should be implanted under flouroscopy or the guidance of bronchoscope visualization. In this study, we evaluated the operation time and safety between OTW stent and a novel through-the-scope (TTS) SEM airway stent. Methods: In this multi-center, randomized, parallel-group superiority study, malignant CAO patients were enrolled randomly assigned (2:1) to the TTS stent implantation group (TTS group) or the standard OTW stent group (OTW group) in six sites across China. The entire process of all surgical procedures was recorded by video. Primary endpoint was the operation time of the airway stent implantation and secondary endpoint was the success rate of the stent implantation as well as its efficacy and safety. Results: From May 15, 2017, to December 30, 2018, 148 patients were enrolled from the six sites. We analyzed 134 patients (including 91 patients from the TTS group and 43 patients from the OTW group) according to the per-protocol set. There were no significant differences in the ages, genders, underlying diseases, and stenosis sites between the two groups. The operation time in the TTS group was significantly shorter than that in the OTW group (104±68 vs. 252±111 seconds, P<0.001). Compared to the OTW group, the efficacy of stent implantation (97.80% vs. 90.70%, P=0.093) and rate of first-time successful stent implantation (78.02% vs. 74.42%, P=0.668) were higher in the TTS group, but did not reach statistically significance. The rates of granulation (28.57% vs. 41.86%, P=0.128) and restenosis (15.38% vs. 30.23%, P=0.064) in the TTS group were slightly lower as compared with the OTW group without achieving statistical significance. Conclusions: The TTS stent implantation procedure time was significantly shorter than that of the OTW airway stent with similar efficacy and complications, which might reduce the risk and flexibility of stent implantation.
AB - Background: Self-expandable metallic (SEM) airway stents are an important approach to treating malignant central airway obstruction (CAO). Standard over-the-while (OTW) stent needs the guidance of a guide-wire. It should be implanted under flouroscopy or the guidance of bronchoscope visualization. In this study, we evaluated the operation time and safety between OTW stent and a novel through-the-scope (TTS) SEM airway stent. Methods: In this multi-center, randomized, parallel-group superiority study, malignant CAO patients were enrolled randomly assigned (2:1) to the TTS stent implantation group (TTS group) or the standard OTW stent group (OTW group) in six sites across China. The entire process of all surgical procedures was recorded by video. Primary endpoint was the operation time of the airway stent implantation and secondary endpoint was the success rate of the stent implantation as well as its efficacy and safety. Results: From May 15, 2017, to December 30, 2018, 148 patients were enrolled from the six sites. We analyzed 134 patients (including 91 patients from the TTS group and 43 patients from the OTW group) according to the per-protocol set. There were no significant differences in the ages, genders, underlying diseases, and stenosis sites between the two groups. The operation time in the TTS group was significantly shorter than that in the OTW group (104±68 vs. 252±111 seconds, P<0.001). Compared to the OTW group, the efficacy of stent implantation (97.80% vs. 90.70%, P=0.093) and rate of first-time successful stent implantation (78.02% vs. 74.42%, P=0.668) were higher in the TTS group, but did not reach statistically significance. The rates of granulation (28.57% vs. 41.86%, P=0.128) and restenosis (15.38% vs. 30.23%, P=0.064) in the TTS group were slightly lower as compared with the OTW group without achieving statistical significance. Conclusions: The TTS stent implantation procedure time was significantly shorter than that of the OTW airway stent with similar efficacy and complications, which might reduce the risk and flexibility of stent implantation.
KW - Central airway obstruction (CAO)
KW - efficacy
KW - flexible bronchoscope
KW - malignant
KW - metallic airway stent
UR - http://www.scopus.com/inward/record.url?scp=85140273658&partnerID=8YFLogxK
U2 - 10.21037/tlcr-22-565
DO - 10.21037/tlcr-22-565
M3 - Article
AN - SCOPUS:85140273658
SN - 2218-6751
VL - 11
SP - 1692
EP - 1701
JO - Translational Lung Cancer Research
JF - Translational Lung Cancer Research
IS - 8
ER -