TY - JOUR
T1 - Coronary artery magnetic resonance imaging
T2 - A patient-tailored approach
AU - Foo, Thomas K.F.
AU - Saranathan, Manojkumar
AU - Hardy, Christopher J.
AU - Ho, Vincent B.
PY - 2000
Y1 - 2000
N2 - Coronary artery magnetic resonance imaging strategies have tended to focus on the use of a single method performed during either breath-holding or free-breathing for all patients. However, significant variations exist among patients in terms of breath-holding ability and respiratory regularity that make the use of a single technique alone not universally successful. Therefore, it is prudent to make available a number of magnetic resonance imaging methods such that an appropriate respiratory motion reduction strategy can be tailored to suit the patient's respiratory pattern and characteristics. A tailored approach that can draw on different image acquisition techniques for coronary artery imaging is presented. A decision tree is proposed to triage patients into imaging regimes with the greatest probability of success, according to the patient's ability to breath-hold or exhibit steady respiration. Methods include volume free-breathing acquisitions using navigator echoes for respiratory monitoring in the 8- to 10-min scan time range, two-dimensional spiral navigators (2- to 3-min scan time), breath-held multislice and vessel-tracking spirals (16- to 20-second scan time), and real-time imaging approaches incorporating adaptive signal averaging. The development of multiple acquisition strategies substantially improves the opportunities to generate high-quality, diagnostic images of the coronary arteries.
AB - Coronary artery magnetic resonance imaging strategies have tended to focus on the use of a single method performed during either breath-holding or free-breathing for all patients. However, significant variations exist among patients in terms of breath-holding ability and respiratory regularity that make the use of a single technique alone not universally successful. Therefore, it is prudent to make available a number of magnetic resonance imaging methods such that an appropriate respiratory motion reduction strategy can be tailored to suit the patient's respiratory pattern and characteristics. A tailored approach that can draw on different image acquisition techniques for coronary artery imaging is presented. A decision tree is proposed to triage patients into imaging regimes with the greatest probability of success, according to the patient's ability to breath-hold or exhibit steady respiration. Methods include volume free-breathing acquisitions using navigator echoes for respiratory monitoring in the 8- to 10-min scan time range, two-dimensional spiral navigators (2- to 3-min scan time), breath-held multislice and vessel-tracking spirals (16- to 20-second scan time), and real-time imaging approaches incorporating adaptive signal averaging. The development of multiple acquisition strategies substantially improves the opportunities to generate high-quality, diagnostic images of the coronary arteries.
KW - Cardiac magnetic resonance imaging
KW - Coronary artery angiography
KW - Pulse sequences
KW - Respiratory compensation
KW - Spiral imaging
UR - http://www.scopus.com/inward/record.url?scp=0034464293&partnerID=8YFLogxK
U2 - 10.1097/00002142-200012000-00009
DO - 10.1097/00002142-200012000-00009
M3 - Review article
C2 - 11153707
AN - SCOPUS:0034464293
SN - 0899-3459
VL - 11
SP - 406
EP - 416
JO - Topics in Magnetic Resonance Imaging
JF - Topics in Magnetic Resonance Imaging
IS - 6
ER -