TY - JOUR
T1 - Crack revision improves fixation of uncemented ha-coated implants compared with reaming
T2 - An experiment in dogs
AU - Baas, Jorgen
AU - Elmengaard, Brian
AU - Jakobsen, Thomas
AU - Bechtold, Joan
AU - Soballe, Kjeld
N1 - Funding Information:
One or more of the authors (JBE, KS) have received funding from the National Institutes of Health (AR4205). The implants were provided unconditionally by Biomet Inc, Warsaw, IN. Each author certifies that his or her institution has approved the animal protocol for this investigation and that all investigations were conducted in conformity with ethical principles of research. Study performed at Orthopaedic Research Laboratory, Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark (specimen preparation, testing and analysis), and Midwest Orthopaedic and Minneapolis Medical Research Foundations, Minneapolis, MN, USA (surgeries).
PY - 2009/10
Y1 - 2009/10
N2 - The crack procedure is a surgical technique for preparing the implant cavity at revision of loose joint replacement components. It disrupts the neocortical bone shell that typically forms around the cavity. Using an animal model, we compared the crack technique with reaming. Twenty micromotion implants were inserted bilaterally into the knees of 10 dogs according to our revision protocol, allowing formation of a standardized revision cavity (loose implant, fibrous tissue, and sclerotic bone rim). Eight weeks later we performed revision surgery. On the control side, in which the neocortex was removed, the cavity was reamed. On the intervention side, in which the neocortex was perforated but left in situ, the cavity was cracked. For revision we used non-motioning hydroxyapatite (HA)-coated, plasma-sprayed titanium implants. Observation after revision was 4 weeks. The implants revised by the crack technique had better mechanical fixation in all mechanical parameters by the push-out test. The crack revisions also provided more new bone formation around the implants compared with the reamed revisions but had no effect on new bone ongrowth. The data suggest using this bone-sparing technique may be superior to reaming in terms of achieving improved early implant fixation of uncemented HA-coated revision implants.
AB - The crack procedure is a surgical technique for preparing the implant cavity at revision of loose joint replacement components. It disrupts the neocortical bone shell that typically forms around the cavity. Using an animal model, we compared the crack technique with reaming. Twenty micromotion implants were inserted bilaterally into the knees of 10 dogs according to our revision protocol, allowing formation of a standardized revision cavity (loose implant, fibrous tissue, and sclerotic bone rim). Eight weeks later we performed revision surgery. On the control side, in which the neocortex was removed, the cavity was reamed. On the intervention side, in which the neocortex was perforated but left in situ, the cavity was cracked. For revision we used non-motioning hydroxyapatite (HA)-coated, plasma-sprayed titanium implants. Observation after revision was 4 weeks. The implants revised by the crack technique had better mechanical fixation in all mechanical parameters by the push-out test. The crack revisions also provided more new bone formation around the implants compared with the reamed revisions but had no effect on new bone ongrowth. The data suggest using this bone-sparing technique may be superior to reaming in terms of achieving improved early implant fixation of uncemented HA-coated revision implants.
UR - http://www.scopus.com/inward/record.url?scp=70349912740&partnerID=8YFLogxK
U2 - 10.1007/s11999-009-0745-6
DO - 10.1007/s11999-009-0745-6
M3 - Article
C2 - 19229662
AN - SCOPUS:70349912740
SN - 0009-921X
VL - 467
SP - 2638
EP - 2643
JO - Clinical Orthopaedics and Related Research
JF - Clinical Orthopaedics and Related Research
IS - 10
ER -