TY - JOUR
T1 - Extending resuscitative endovascular balloon occlusion of the aorta
T2 - Endovascular variable aortic control in a lethal model of hemorrhagic shock
AU - Williams, Timothy Keith
AU - Neff, Lucas P.
AU - Johnson, Michael Austin
AU - Ferencz, Sarah Ashley
AU - Davidson, Anders J.
AU - Russo, Rachel M.
AU - Rasmussen, Todd E.
N1 - Publisher Copyright:
Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2016
Y1 - 2016
N2 - BACKGROUND: The duration of use and efficacy of resuscitative endovascular balloon occlusion of the aorta (REBOA) is limited by distal ischemia. We developed a hybrid endovascular-extracorporeal circuit variable aortic control (VAC) device to extend REBOA duration in a lethal model of hemorrhagic shock to serve as an experimental surrogate to further the development of endovascular VAC (EVAC) technologies. METHODS: Nine Yorkshire-cross swinewere anesthetized, instrumented, splenectomized, and subjected to 30%liver amputation. Following a short period of uncontrolled hemorrhage, REBOAwas instituted for 20 minutes. Automated variable occlusion in response to changes in proximal mean arterial pressure was applied for the remaining 70 minutes of the intervention phase using the automated extracorporeal circuit. Damage-control surgery and whole blood resuscitation then occurred, and the animals were monitored for a total of 6 hours. RESULTS: Seven animals survived the initial surgical preparation. After 20 minutes of complete REBOA, regulated flow was initiated through the extracorporeal circuit to simulate VAC and provide perfusion to distal tissue beds during the 90-minute intervention phase. Two animals required circuit occlusion for salvage, while five animals tolerated sustained, escalating restoration of distal blood flow before surgical hemorrhage control. Animals tolerating distal flow had preserved renal function, maintained proximal blood pressure, and rapidly weaned from complete REBOA. CONCLUSION: We combined a novel automated, extracorporeal circuit with complete REBOA to achieve EVAC in a swine model of uncontrolled hemorrhage. Our approach regulated proximal aortic pressure, alleviated supranormal values above the balloon, and provided controlled distal aortic perfusion that reduced ischemia without inducing intolerable bleeding. This experimental model serves as a temporary surrogate to guide future EVAC catheter designs that may provide transformational approaches to hemorrhagic shock.
AB - BACKGROUND: The duration of use and efficacy of resuscitative endovascular balloon occlusion of the aorta (REBOA) is limited by distal ischemia. We developed a hybrid endovascular-extracorporeal circuit variable aortic control (VAC) device to extend REBOA duration in a lethal model of hemorrhagic shock to serve as an experimental surrogate to further the development of endovascular VAC (EVAC) technologies. METHODS: Nine Yorkshire-cross swinewere anesthetized, instrumented, splenectomized, and subjected to 30%liver amputation. Following a short period of uncontrolled hemorrhage, REBOAwas instituted for 20 minutes. Automated variable occlusion in response to changes in proximal mean arterial pressure was applied for the remaining 70 minutes of the intervention phase using the automated extracorporeal circuit. Damage-control surgery and whole blood resuscitation then occurred, and the animals were monitored for a total of 6 hours. RESULTS: Seven animals survived the initial surgical preparation. After 20 minutes of complete REBOA, regulated flow was initiated through the extracorporeal circuit to simulate VAC and provide perfusion to distal tissue beds during the 90-minute intervention phase. Two animals required circuit occlusion for salvage, while five animals tolerated sustained, escalating restoration of distal blood flow before surgical hemorrhage control. Animals tolerating distal flow had preserved renal function, maintained proximal blood pressure, and rapidly weaned from complete REBOA. CONCLUSION: We combined a novel automated, extracorporeal circuit with complete REBOA to achieve EVAC in a swine model of uncontrolled hemorrhage. Our approach regulated proximal aortic pressure, alleviated supranormal values above the balloon, and provided controlled distal aortic perfusion that reduced ischemia without inducing intolerable bleeding. This experimental model serves as a temporary surrogate to guide future EVAC catheter designs that may provide transformational approaches to hemorrhagic shock.
KW - Aortic occlusion
KW - Endovascular variable aortic control
KW - Hemorrhage control
KW - REBOA
KW - Swine
UR - http://www.scopus.com/inward/record.url?scp=84963677394&partnerID=8YFLogxK
U2 - 10.1097/TA.0000000000001075
DO - 10.1097/TA.0000000000001075
M3 - Article
C2 - 27070441
AN - SCOPUS:84963677394
SN - 2163-0755
VL - 81
SP - 294
EP - 301
JO - Journal of Trauma and Acute Care Surgery
JF - Journal of Trauma and Acute Care Surgery
IS - 2
ER -