TY - JOUR
T1 - Field switching of microfabricated metamagnetic FeRh MRI contrast agents
AU - Dodd, Stephen
AU - Gudino, Natalia
AU - Zadorozhnii, Oleksii
AU - Staňo, Michal
AU - Hajduček, Jan
AU - Arregi, Jon Ander
AU - Morris, H. Douglas
AU - Uhlíř, Vojtěch
AU - Barbic, Mladen
AU - Koretsky, Alan P.
N1 - Publisher Copyright:
© This is a U.S. Government work and not under copyright protection in the US; foreign copyright protection may apply 2025.
PY - 2025/12
Y1 - 2025/12
N2 - In a step towards generating switchable MRI cellular labels, we demonstrate in-situ field switching of micron scale metamagnetic Iron-Rhodium (FeRh) thin film particles. A thin-film (200 nm) FeRh sample was fabricated and patterned into an array of progressively smaller squares with sizes ranging from 500 μm down to 1 μm. The large first order phase change from antiferromagnetic to ferromagnetic state was characterized using vibrating sample magnetometry, magnetic force microscopy, and MRI. Room temperature MRI experiments sensitive to the local magnetic field surrounding the particles demonstrated the low moment state (OFF MRI contrast) at 4.7T and high moment state (ON MRI contrast) at 11.7T for the array where sizes down to 2–3 μm were observed in MRI at 50 μm resolution. The expected temperature dependent MRI contrast change was seen at 4.7T, where 10 μm particles could be observed at 150 μm resolution in the ON state. A shielded MRI insert, used to temporarily increase or decrease the magnetic field up to 0.77T amplitude, was used to reversibly switch the particle array at constant temperature and blink the particles ON and OFF at 4.7T. This work demonstrates the MRI contrast switching potential for FeRh particles with biological cell dimensions, and the use of magnetic field pulses for reversible MRI label contrast control.
AB - In a step towards generating switchable MRI cellular labels, we demonstrate in-situ field switching of micron scale metamagnetic Iron-Rhodium (FeRh) thin film particles. A thin-film (200 nm) FeRh sample was fabricated and patterned into an array of progressively smaller squares with sizes ranging from 500 μm down to 1 μm. The large first order phase change from antiferromagnetic to ferromagnetic state was characterized using vibrating sample magnetometry, magnetic force microscopy, and MRI. Room temperature MRI experiments sensitive to the local magnetic field surrounding the particles demonstrated the low moment state (OFF MRI contrast) at 4.7T and high moment state (ON MRI contrast) at 11.7T for the array where sizes down to 2–3 μm were observed in MRI at 50 μm resolution. The expected temperature dependent MRI contrast change was seen at 4.7T, where 10 μm particles could be observed at 150 μm resolution in the ON state. A shielded MRI insert, used to temporarily increase or decrease the magnetic field up to 0.77T amplitude, was used to reversibly switch the particle array at constant temperature and blink the particles ON and OFF at 4.7T. This work demonstrates the MRI contrast switching potential for FeRh particles with biological cell dimensions, and the use of magnetic field pulses for reversible MRI label contrast control.
UR - http://www.scopus.com/inward/record.url?scp=85216608298&partnerID=8YFLogxK
U2 - 10.1038/s41598-025-85384-6
DO - 10.1038/s41598-025-85384-6
M3 - Article
C2 - 39843509
AN - SCOPUS:85216608298
SN - 2045-2322
VL - 15
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 2779
ER -