TY - JOUR
T1 - Rapid determination of N,N-diethyl-m-toluamide and permethrin in human plasma by gas chromatography-mass spectrometry and pyridostigmine bromide by high-performance liquid chromatography
AU - Cherstniakova, Svetlana A.
AU - Garcia, Gregory E.
AU - Strong, John
AU - Bi, Daoqin
AU - Weitz, Julie
AU - Roy, Michael J.
AU - Cantilena, Louis R.
N1 - Funding Information:
This study was supported by U.S. Army Grant 600-083-00000-00-100435.
PY - 2006
Y1 - 2006
N2 - A rapid and highly sensitive gas chromatography-mass spectrometry (GC-MS) method for simultaneous determination of N,N-diethyl-m-toluamide (DEET) and permethrin with 2H10-phenanthrene (98 atom %) as an internal standard and a separate external standard high-performance liquid chromatography (HPLC) method for pyridostigmine bromide (PB) determination in human plasma were developed and validated. The GC-MS method for DEET and permethrin quantification utilizes a one-step extraction with tert-butylmethylether. The HPLC method for PB quantification involves a solid-phase extraction and UV detection. The range of the analytical method for DEET and permethrin was 1 ng/mL to 100 ng/mL and for PB was 5 ng/mL to 100 ng/mL. Recovery from plasma proved to be more than 80%. The intraday precision ranged from 1.3% to 8% for DEET, from 2.1% to 11.4% for permethrin, and from 3.0% to 4.8% for PB. The interday precision was 3% for DEET, ranged from 5% to 9% for permethrin, and from 5% to 9% for PB. The accuracy for the limit of quantification was 92% ± 8% relative standard deviation (RSD) for DEET, 112% ± 11% RSD for permethrin, and 109% ± 5% RSD for PB. All 3 compounds were stable in human plasma at -80°C for at least 12 months and after 2 freeze-thaw cycles with RSD values ranging from 7.1% (DEET, 80 ng/mL) to 8.1% (DEET, 8 ng/mL), from 2.3% (permethrin, 80 ng/mL) to 11.6 % (permethrin, 8 ng/mL), and from 0.2% (PB, 80 ng/mL) to 3.6% (PB, 8 ng/mL). Both methods were successfully applied to pharmacokinetic/pharmacodynamic studies of combined exposure of DEET (skin application), permethrin (treated uniforms), and PB (30 mg orally three times/day for four doses) in healthy volunteers (n = 81).
AB - A rapid and highly sensitive gas chromatography-mass spectrometry (GC-MS) method for simultaneous determination of N,N-diethyl-m-toluamide (DEET) and permethrin with 2H10-phenanthrene (98 atom %) as an internal standard and a separate external standard high-performance liquid chromatography (HPLC) method for pyridostigmine bromide (PB) determination in human plasma were developed and validated. The GC-MS method for DEET and permethrin quantification utilizes a one-step extraction with tert-butylmethylether. The HPLC method for PB quantification involves a solid-phase extraction and UV detection. The range of the analytical method for DEET and permethrin was 1 ng/mL to 100 ng/mL and for PB was 5 ng/mL to 100 ng/mL. Recovery from plasma proved to be more than 80%. The intraday precision ranged from 1.3% to 8% for DEET, from 2.1% to 11.4% for permethrin, and from 3.0% to 4.8% for PB. The interday precision was 3% for DEET, ranged from 5% to 9% for permethrin, and from 5% to 9% for PB. The accuracy for the limit of quantification was 92% ± 8% relative standard deviation (RSD) for DEET, 112% ± 11% RSD for permethrin, and 109% ± 5% RSD for PB. All 3 compounds were stable in human plasma at -80°C for at least 12 months and after 2 freeze-thaw cycles with RSD values ranging from 7.1% (DEET, 80 ng/mL) to 8.1% (DEET, 8 ng/mL), from 2.3% (permethrin, 80 ng/mL) to 11.6 % (permethrin, 8 ng/mL), and from 0.2% (PB, 80 ng/mL) to 3.6% (PB, 8 ng/mL). Both methods were successfully applied to pharmacokinetic/pharmacodynamic studies of combined exposure of DEET (skin application), permethrin (treated uniforms), and PB (30 mg orally three times/day for four doses) in healthy volunteers (n = 81).
UR - http://www.scopus.com/inward/record.url?scp=33646182004&partnerID=8YFLogxK
U2 - 10.1093/jat/30.1.21
DO - 10.1093/jat/30.1.21
M3 - Article
C2 - 16620527
AN - SCOPUS:33646182004
SN - 0146-4760
VL - 30
SP - 21
EP - 26
JO - Journal of Analytical Toxicology
JF - Journal of Analytical Toxicology
IS - 1
ER -