Skip to main navigation Skip to search Skip to main content

Salivary caffeine concentrations are comparable to plasma concentrations in preterm infants receiving extended caffeine therapy

  • Nicole R. Dobson*
  • , Xiaoxi Liu
  • , Lawrence M. Rhein
  • , Robert A. Darnall
  • , Michael J. Corwin
  • , Betty L. McEntire
  • , Robert M. Ward
  • , Laura P. James
  • , Catherine M.T. Sherwin
  • , Timothy C. Heeren
  • , Carl E. Hunt
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

42 Scopus citations

Abstract

Aims: Caffeine concentrations in preterm infants are usually measured in the blood. However, salivary assays may provide a valid and practical alternative. The present study explored the validity and clinical utility of salivary caffeine concentrations as an alternative to blood concentrations and developed a novel plasma/salivary caffeine distribution model. Methods: Paired salivary and plasma samples were obtained in 29 infants. Salivary samples were obtained using a commercially available salivary collection system. Caffeine concentrations in the saliva and plasma were determined using high-performance liquid chromatography. A population pharmacokinetic (PK) model was developed using NONMEM 7.3. Results: The mean (± standard deviation) gestational age (GA) at birth and birth weight were 27.9 ± 2.1 weeks and 1171.6 ± 384.9 g, respectively. Paired samples were obtained at a mean postmenstrual age (PMA) of 35.5 ± 1.1 weeks. The range of plasma caffeine concentrations was 9.5–54.1 μg ml−1, with a mean difference (95% confidence interval) between plasma and salivary concentrations of −0.18 μg ml−1(−1.90, 1.54). Salivary and plasma caffeine concentrations were strongly correlated (Pearson's correlation coefficient = 0.87, P < 0.001). Caffeine PK in plasma and saliva was simultaneously described by a three-compartment recirculation model. Current body weight, birth weight, GA, PMA and postnatal age were not significantly correlated with any PK parameter. Conclusions: Salivary sampling provides an easy, non-invasive method for measuring caffeine concentrations. Salivary concentrations correlate highly with plasma concentrations. Caffeine PK in saliva and plasma are well described by a three-compartment recirculation model.

Original languageEnglish
Pages (from-to)754-761
Number of pages8
JournalBritish Journal of Clinical Pharmacology
DOIs
StatePublished - 2016

Keywords

  • caffeine
  • pharmacokinetic model
  • preterm infant
  • saliva

Fingerprint

Dive into the research topics of 'Salivary caffeine concentrations are comparable to plasma concentrations in preterm infants receiving extended caffeine therapy'. Together they form a unique fingerprint.

Cite this