Skip to main navigation Skip to search Skip to main content

Short Echo-Time Spiral MRSI Versus Single-Voxel Spectroscopy in the Human Brain at 3 Tesla With Semi-LASER Localization

  • Young Woo Park
  • , Isaac M Adanyeguh
  • , Pierre-Gilles Henry
  • , Dinesh K Deelchand

Research output: Contribution to journal › Article › peer-review

Abstract

PURPOSE: Magnetic resonance spectroscopy techniques are widely used to non-invasively study brain metabolism. Despite advances in magnetic resonance spectroscopic imaging (MRSI), there is a notable absence of research on comparing fast non-Cartesian MRSI with single-voxel spectroscopy (SVS), limiting our understanding of its performance and applicability. In this study, we compared the spectral quality and metabolite concentrations obtained using short-TE 2D spiral MRSI and SVS in the same region in the human brain at 3T.

METHODS: Five healthy subjects were scanned at 3T. 2D spiral MRSI data were acquired in a transverse slice through the posterior cingulate cortex (PCC), while the SVS volume was placed within the PCC region. Both techniques employed the standardized semi-LASER sequence for localization. All data were processed in Matlab and fitted with LCModel.

RESULTS: Visual inspection suggested comparable overall spectral quality between the two acquisitions. Quantitatively, however, the PCC voxel measured with MRSI exhibited lower signal-to-noise ratio (SNR) compared to SVS at identical scan times, when the SVS voxel matched the effective MRSI voxel. Consistent with lower SNR, metabolite quantification showed higher Cramer-Rao lower bounds with MRSI. In addition, concentrations of glutamate and glutamate plus glutamine were lower with MRSI.

CONCLUSION: Our findings demonstrate that the quality of semi-LASER localized short-TE spiral MRSI spectra is very comparable to that of semi-LASER localized SVS spectra. Small metabolic-specific concentration differences may be due to different WM/GM tissue weighting within the voxel (slice selection profile in SVS vs. point-spread function in MRSI) and different SNR between the two techniques.

Original languageEnglish
Pages (from-to)1524-1533
Number of pages10
JournalMagnetic Resonance in Medicine
Volume96
Issue number4
DOIs
StatePublished - Oct 2026
Externally publishedYes

Keywords

  • Humans
  • Magnetic Resonance Spectroscopy/methods
  • Male
  • Adult
  • Brain/metabolism
  • Female
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Magnetic Resonance Imaging/methods
  • Algorithms

Fingerprint

Dive into the research topics of 'Short Echo-Time Spiral MRSI Versus Single-Voxel Spectroscopy in the Human Brain at 3 Tesla With Semi-LASER Localization'. Together they form a unique fingerprint.