TY - JOUR
T1 - Small changes, big effects
T2 - The hemodynamics of partial and complete aortic occlusion to inform next generation resuscitation techniques and technologies
AU - Austin Johnson, M.
AU - Davidson, Anders J.
AU - Russo, Rachel M.
AU - Ferencz, Sarah Ashley E.
AU - Gotlib, Oren
AU - Rasmussen, Todd E.
AU - Neff, Lucas P.
AU - Williams, Timothy K.
N1 - Publisher Copyright:
© 2017 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2017
Y1 - 2017
N2 - BACKGROUND: The transition from complete aortic occlusion during resuscitative endovascular balloon occlusion of the aorta can be associated with hemodynamic instability. Technique refinements and new technologies have been proposed to minimize this effect. In order to inform new techniques and technology, we examined the relationship between blood pressure and aortic flow during the restoration of systemic circulation following aortic occlusion at progressive levels of hemorrhage. METHODS: An automated supraceliac aortic clamp, capable of continuously variable degrees of occlusion, was applied in seven swine. The swine underwent stepwise removal of 40% of their total blood volume in four equal aliquots. After each aliquot, progressive luminal narrowing to the point of complete aortic occlusion was achieved over 5 minutes, sustained for 5 minutes, and then released over 5 minutes. Proximal and distal blood pressure and distal aortic flow were continuously recorded throughout the study. RESULTS: Upon release of the clamp, hyperemic aortic flow was observed following 10% and 20% hemorrhage (1,599 ± 785 mL/min, p < 0.01; and 1,070 ± 396 mL/min, p < 0.01, respectively). Proximal blood pressure exhibited a nonlinear relationship to aortic flow during clamp removal; however, distal blood pressure increased linearly with distal flow upon clamp opening across all hemorrhage volumes. CONCLUSIONS: Hyperemic blood flow following return of circulation may contribute to cardiovascular collapse. Reintroduction of systemic blood flow after aortic occlusion should be guided by distal blood pressure rather than proximal pressure. Awareness of hemodynamic physiology during aortic occlusion is of paramount importance to the clinical implementation of next-generation resuscitative endovascular balloon occlusion of the aorta techniques and technologies.
AB - BACKGROUND: The transition from complete aortic occlusion during resuscitative endovascular balloon occlusion of the aorta can be associated with hemodynamic instability. Technique refinements and new technologies have been proposed to minimize this effect. In order to inform new techniques and technology, we examined the relationship between blood pressure and aortic flow during the restoration of systemic circulation following aortic occlusion at progressive levels of hemorrhage. METHODS: An automated supraceliac aortic clamp, capable of continuously variable degrees of occlusion, was applied in seven swine. The swine underwent stepwise removal of 40% of their total blood volume in four equal aliquots. After each aliquot, progressive luminal narrowing to the point of complete aortic occlusion was achieved over 5 minutes, sustained for 5 minutes, and then released over 5 minutes. Proximal and distal blood pressure and distal aortic flow were continuously recorded throughout the study. RESULTS: Upon release of the clamp, hyperemic aortic flow was observed following 10% and 20% hemorrhage (1,599 ± 785 mL/min, p < 0.01; and 1,070 ± 396 mL/min, p < 0.01, respectively). Proximal blood pressure exhibited a nonlinear relationship to aortic flow during clamp removal; however, distal blood pressure increased linearly with distal flow upon clamp opening across all hemorrhage volumes. CONCLUSIONS: Hyperemic blood flow following return of circulation may contribute to cardiovascular collapse. Reintroduction of systemic blood flow after aortic occlusion should be guided by distal blood pressure rather than proximal pressure. Awareness of hemodynamic physiology during aortic occlusion is of paramount importance to the clinical implementation of next-generation resuscitative endovascular balloon occlusion of the aorta techniques and technologies.
KW - Aortic physiology
KW - Noncompressible torso hemorrhage
KW - Partial REBOA
KW - REBOA
UR - http://www.scopus.com/inward/record.url?scp=85016051357&partnerID=8YFLogxK
U2 - 10.1097/TA.0000000000001446
DO - 10.1097/TA.0000000000001446
M3 - Article
C2 - 28338590
AN - SCOPUS:85016051357
SN - 2163-0755
VL - 82
SP - 1106
EP - 1111
JO - Journal of Trauma and Acute Care Surgery
JF - Journal of Trauma and Acute Care Surgery
IS - 6
ER -