N2 - This study measured the vertical displacement of three kinds of cementless tibial components [Porous Coated Anatomical (PCA), Tricon, and Whiteside], under eccentric loading up to 2,225 N. Displacement between the tibial tray and the proximal tibia was measured with linear variable differential transformers at the anterior and posterior side when anteriorly or posteriorly loaded, and at the medial and lateral side when medially or laterally loaded. The general pattern of motion was sinking at the loaded side and lift‐off at the opposite side and lift‐off at the opposite side. Lift‐off opposite the loaded side was fairly small for all components at all measurement sites. Among the three components, the Whiteside showed the smallest displacements. The Tricon (when anteriorly or posteriorly loaded), and the PCA (when medially or laterally loaded) showed sinking at the loaded side. Anterior screw fixation of the PCA was not effective in preventing anterior lift‐off. The tilting motion of the tibial components obseved in this study implies instability of the initial fixation, which could possibly compromise bony ingrowth. Furthermore, this tilting could cause uneven distribution of load, and potentially result in fracture of the underlying bone.
AB - This study measured the vertical displacement of three kinds of cementless tibial components [Porous Coated Anatomical (PCA), Tricon, and Whiteside], under eccentric loading up to 2,225 N. Displacement between the tibial tray and the proximal tibia was measured with linear variable differential transformers at the anterior and posterior side when anteriorly or posteriorly loaded, and at the medial and lateral side when medially or laterally loaded. The general pattern of motion was sinking at the loaded side and lift‐off at the opposite side and lift‐off at the opposite side. Lift‐off opposite the loaded side was fairly small for all components at all measurement sites. Among the three components, the Whiteside showed the smallest displacements. The Tricon (when anteriorly or posteriorly loaded), and the PCA (when medially or laterally loaded) showed sinking at the loaded side. Anterior screw fixation of the PCA was not effective in preventing anterior lift‐off. The tilting motion of the tibial components obseved in this study implies instability of the initial fixation, which could possibly compromise bony ingrowth. Furthermore, this tilting could cause uneven distribution of load, and potentially result in fracture of the underlying bone.
KW - Cementless tibial component
KW - Initial stability
KW - Micromovement
UR - http://www.scopus.com/inward/record.url?scp=0025164982&partnerID=8YFLogxK
U2 - 10.1002/jor.1100080108
DO - 10.1002/jor.1100080108
M3 - Article
C2 - 2293635
AN - SCOPUS:0025164982
SN - 0736-0266
VL - 8
SP - 64
EP - 71
JO - Journal of Orthopaedic Research
JF - Journal of Orthopaedic Research
IS - 1
ER -