TY - JOUR
T1 - The effect of stainless steel, cobalt-chromium, titanium alloy, and titanium on the respiratory burst activity of human polymorphonuclear leukocytes
AU - Pascual, A.
AU - Tsukayama, D. T.
AU - Wicklund, B. H.
AU - Bechtold, J. E.
AU - Merritt, K.
AU - Peterson, P. K.
AU - Gustilo, R. B.
PY - 1992
Y1 - 1992
N2 - Although infection is a serious complication associated with the use of orthopedic prosthetic implants, the impact of the metal used in these devices on host defense is poorly understood. The authors investigated the effect of stainless steel, titanium, titanium alloy, and cobalt-chromium alloy on the respiratory burst of polymorphonuclear leukocytes (PMN), a vital component of bactericidal activity. In the presence of stainless steel powder or supernatants obtained from the incubation of stainless steel in buffer, superoxide production by PMN was significantly impaired. Titanium, titanium alloy, and cobalt-chrome alloy had no significant effect on superoxide production. Nickel and chromium, the only metal ions detectable in the stainless steel supernatant, did not impair superoxide production when tested at concentrations similar to those found in the supernatant. Inhibition of PMN superoxide production may play a role in the establishment and persistence of stainless steel device-related infections.
AB - Although infection is a serious complication associated with the use of orthopedic prosthetic implants, the impact of the metal used in these devices on host defense is poorly understood. The authors investigated the effect of stainless steel, titanium, titanium alloy, and cobalt-chromium alloy on the respiratory burst of polymorphonuclear leukocytes (PMN), a vital component of bactericidal activity. In the presence of stainless steel powder or supernatants obtained from the incubation of stainless steel in buffer, superoxide production by PMN was significantly impaired. Titanium, titanium alloy, and cobalt-chrome alloy had no significant effect on superoxide production. Nickel and chromium, the only metal ions detectable in the stainless steel supernatant, did not impair superoxide production when tested at concentrations similar to those found in the supernatant. Inhibition of PMN superoxide production may play a role in the establishment and persistence of stainless steel device-related infections.
UR - http://www.scopus.com/inward/record.url?scp=0026783940&partnerID=8YFLogxK
U2 - 10.1097/00003086-199207000-00039
DO - 10.1097/00003086-199207000-00039
M3 - Article
C2 - 1319292
AN - SCOPUS:0026783940
SN - 0009-921X
VL - 280
SP - 281
EP - 288
JO - Clinical Orthopaedics and Related Research
JF - Clinical Orthopaedics and Related Research
ER -