TY - JOUR
T1 - The effects of extended-wear hearing aids on the localization accuracy of listeners with normal audiometric thresholds
AU - Spencer, Nathaniel J.
AU - Sherlock, La Guinn P.
AU - Pryor, Nina
AU - Iyer, Nandini
AU - Gallagher, Hilary L.
AU - Brungart, Douglas S.
N1 - Publisher Copyright:
© 2024 U.S. Government.
PY - 2024/7/1
Y1 - 2024/7/1
N2 - Extended-wear hearing aids (EWHAs) are small broadband analog amplification devices placed deeply enough in the ear canal to preserve most of the cues in the head-related transfer function. However, little is known about how EWHAs affect localization accuracy for normal hearing threshold (NHT) listeners. In this study, eight NHT participants were fitted with EWHAs and localized broadband sounds of different durations (250 ms and 4 s) and stimulus intensities (40, 50, 60, 70, and 80 dBA) in a spherical speaker array. When the EWHAs were in the active mode, localization accuracy was only slightly degraded relative to open-ear performance. However, when the EWHAs were turned off, localization performance was substantially degraded even at the highest stimulus intensities. An electro-acoustical evaluation of the EWHAs showed minimal effects of dynamic range compression on the signals and good preservation of the signal pattern for vertical polar sound localization. Between-study comparisons suggest that EWHA active mode localization accuracy is favorable compared to conventional active earplugs, and EWHA passive mode localization accuracy is comparable to conventional passive earplugs. These results suggest that the deep-insertion analog design of the EWHA is generally better at preserving localization accuracy of NHT listeners than conventional earplug devices.
AB - Extended-wear hearing aids (EWHAs) are small broadband analog amplification devices placed deeply enough in the ear canal to preserve most of the cues in the head-related transfer function. However, little is known about how EWHAs affect localization accuracy for normal hearing threshold (NHT) listeners. In this study, eight NHT participants were fitted with EWHAs and localized broadband sounds of different durations (250 ms and 4 s) and stimulus intensities (40, 50, 60, 70, and 80 dBA) in a spherical speaker array. When the EWHAs were in the active mode, localization accuracy was only slightly degraded relative to open-ear performance. However, when the EWHAs were turned off, localization performance was substantially degraded even at the highest stimulus intensities. An electro-acoustical evaluation of the EWHAs showed minimal effects of dynamic range compression on the signals and good preservation of the signal pattern for vertical polar sound localization. Between-study comparisons suggest that EWHA active mode localization accuracy is favorable compared to conventional active earplugs, and EWHA passive mode localization accuracy is comparable to conventional passive earplugs. These results suggest that the deep-insertion analog design of the EWHA is generally better at preserving localization accuracy of NHT listeners than conventional earplug devices.
UR - http://www.scopus.com/inward/record.url?scp=85198925361&partnerID=8YFLogxK
U2 - 10.1121/10.0026596
DO - 10.1121/10.0026596
M3 - Article
C2 - 39013035
AN - SCOPUS:85198925361
SN - 0001-4966
VL - 156
SP - 475
EP - 488
JO - Journal of the Acoustical Society of America
JF - Journal of the Acoustical Society of America
IS - 1
ER -